Manual 2100-508Page 1 of 25INSTALLATION INSTRUCTIONSWALL MOUNTEDPACKAGE AIR CONDITIONERSMODELSW18A1 W18L1W24A1 W24L1W30A1 W30L1W36A1 W36L1W42A1 W42L
Manual 2100-508Page 10 of 25FIGURE 3CW42A1, W42L1, W48A1, W48L1, W60A1, W60L1MOUNTING INSTRUCTIONS
Manual 2100-508Page 11 of 25FIGURE 4ELECTRIC HEAT CLEARANCEW30A1, W30L1, W36A1, W36L1, W42A1, W42L1, W48A1, W48L1, W60A1, W60L1 WARNINGA mini
Manual 2100-508Page 12 of 25FIGURE 5WALL MOUNTING INSTRUCTIONSFIGURE 6WALL MOUNTING INSTRUCTIONSSEE FIGURE 3 – MOUNTING INSTRUCTIONSSEE UNIT DIMENS
Manual 2100-508Page 13 of 25FIGURE 7COMMON WALL MOUNTING INSTALLATIONS
Manual 2100-508Page 14 of 25WIRING – MAIN POWERRefer to the unit rating plate for wire sizing informationand maximum fuse or “HACR” type circuit bre
Manual 2100-508Page 15 of 25START UPTHESE UNITS REQUIRE R-410AREFRIGERANT AND POLYOLESTER OIL.GENERAL:1. Use separate service equipment to avoid cross
Manual 2100-508Page 16 of 25START UP (Continued)IMPORTANT INSTALLER NOTEFor improved start up performance wash the indoor coilwith a dish washing dete
Manual 2100-508Page 17 of 25SEQUENCE OF OPERATIONCOOLING – Circuit R-Y makes at thermostat pullingin compressor contactor, starting the compressor a
Manual 2100-508Page 18 of 25TROUBLESHOOTINGFIGURE 8FAN BLADE SETTINGMIS-1724TABLE 1FAN BLADE DIMENSIONREMOVAL OF FAN SHROUD1. Disconnect all power t
Manual 2100-508Page 19 of 25TABLE 3COOLING PRESSURE TABLEAir Temperature Entering Outdoor Coil °FLow side pressure ± 2 PSIGHigh side pressure ± 5 PS
Manual 2100-508Page 2 of 25ContentsFiguresFigure 1 Fresh Air Damper Assembly ... 5Figure 2 Unit Dimensions ...
Manual 2100-508Page 20 of 25TABLE 41 Maximum size of the time delay fuse or HACR type circuit breaker for protection of field wiring conductors.2 B
Manual 2100-508Page 21 of 25TABLE 51 Maximum size of the time delay fuse or HACR type circuit breaker for protection of field wiring conductors.2 B
Manual 2100-508Page 22 of 25TABLE 6RECOMMENDED AIRFLOWTABLE 7INDOOR BLOWER PERFORMANCETABLE 8MAXIMUM ESP OF OPERATIONELECTRIC HEAT ONLYValues shown
Manual 2100-508Page 23 of 25TABLE 9ELECTRIC HEATsledoM1-V0421-V8023-V0423-V8023-V064WKspmAHUTBspmAHUTBspmAHUTBspmAHUTBspmAHUTB47.61056314.410420158.0
Manual 2100-508Page 24 of 25W18*1-AW24*1-AW24*1-BW24*1-CW30*1-AW30*1-BW30*1-CW36*1-AW36*1-BW36*1-CW42*1-AW42*1-BW42*1-CW48*1-AW48*1-BW48*1-CW60*1-AW60
Manual 2100-508Page 25 of 25TABLE 11VENT & CONTROL OPTIONSW18, W24W30, W36W42, W48, W60rebmuNtraPnoitpircseD41-CMCTDO XXX51-CMC)esahP-1V032(tiKtr
Manual 2100-508Page 3 of 25GETTING OTHER INFORMATION AND PUBLICATIONSThese publications can help you install the airconditioner or heat pump. You can
Manual 2100-508Page 4 of 25WALL MOUNT GENERAL INFORMATIONAIR CONDITIONER WALL MOUNT MODEL NOMENCLATUREW 42 A 1– A 10 X X X X X ANOTE: Vent options X,
Manual 2100-508Page 5 of 25DUCT WORKAll duct work, supply and return, must be properly sizedfor the design airflow requirement of the equipment. AirC
Manual 2100-508Page 6 of 25sseccAecivreSrofderiuqeRsecnaraelCwolfriAresnednoCetauqedAdnaSLEDOM EDISTFEL EDISTHGIRA63W,A03W,A42W,A81W "51 "02
Manual 2100-508Page 7 of 25SIDE VIEWBACK VIEWFRONT VIEW*Optional top outlet (factory installed only) for W30A and W36A models only.FIGURE 2SIDE VIEWF
Manual 2100-508Page 8 of 25FIGURE 3AW18A1, W18L1, W24A1, W24L1MOUNTING INSTRUCTIONS
Manual 2100-508Page 9 of 25FIGURE 3BW30A1, W30L1, W36A1, W36L1MOUNTING INSTRUCTIONS