MIS-656
© Copyright 2002
Manual No.: 2100-404
Supersedes:
File: Volume III, Tab 16
Date: 04-01-02
Bard Manufacturing Company
Bryan, Ohio 43506
Since 1914...moving ahead just as planned.
Models:
WA302
WA372
WALL MOUNTED PACKAGED
AIR CONDITIONER
INSTALLATION
INSTRUCTIONS
Vedere la pagina 0
1 2 3 4 5 6 ... 18 19

Sommario

Pagina 1 - Bryan, Ohio 43506

MIS-656© Copyright 2002Manual No.: 2100-404Supersedes:File: Volume III, Tab 16Date: 04-01-02Bard Manufacturing CompanyBryan, Ohio 43506Since 1914...m

Pagina 2 - Contents

Manual 2100-404Page 8FIGURE 3MOUNTING INSTRUCTIONSNOTE: It is recommended that a bead of silicone caulking beplaced behind the side mounting flan

Pagina 3 - THESE PUBLISHERS:

Manual 2100-404Page 9FIGURE 4WALL-MOUNTING INSTRUCTIONSMIS-549FIGURE 5WALL-MOUNTING INSTRUCTIONSMIS-548MIS-311MIS-311MIS-311SEE FIGURE 3 – MOUN

Pagina 4 - WA372–A10X XXXXA

Manual 2100-404Page 10MIS-550FIGURE 6COMMON WALL-MOUNTING INSTALLATIONS

Pagina 5 - Page 3

Manual 2100-404Page 11Side section view of supply air duct forwall mounted unit showing 1/4 inchclearance to combustible surfaces.FIGURE 7ELECTRIC

Pagina 6 - SHIPPING DAMAGE

Manual 2100-404Page 12MIS-1373CFIGURE 8LOW VOLTAGE WIRING

Pagina 7 - CAUTION

Manual 2100-404Page 13IMPORTANT INSTALLER NOTEFor improved start-up performance, wash the indoorcoil with a dishwasher detergent.HIGH PRESSURE SWIT

Pagina 8 - WARNING

Manual 2100-404Page 14Alarm Relay OutputAlarm terminal is output connection for applicationswhere alarm relay is employed. This terminal ispowere

Pagina 9 - WIRING — LOW VOLTAGE WIRING

Manual 2100-404Page 15TROUBLESHOOTINGThe suction line temperatures in Table 8 are based upon80ºF dry bulb/67ºF wet bulb (50 percent R.H.)temperatur

Pagina 10 - MOUNTING INSTRUCTIONS

Manual 2100-404Page 16jLow side pressure ± 2 psigHigh side pressure ± 5 psigTables are based upon rated CFM (airflow) across the evaporator coil a

Pagina 11 - FIGURE 5

Manual 2100-404Page 17jThese heater packages not suitable for installation in top outlet models.NOTE: Top outlet models are available only as fac

Pagina 12 - FIGURE 6

ContentsiStart UpImportant Installer Note ... 13High Pressure Switch ...

Pagina 13 - WARNING

Manual 2100-404Page 1Getting Other Information and PublicationsThese publications can help you install the airconditioner or heat pump. You can usu

Pagina 14 - LOW VOLTAGE WIRING

Manual 2100-404Page 2WALL MOUNT GENERAL INFORMATIONAIR CONDITIONER WALL MOUNT MODEL NOMENCLATUREKWWA372–A10X XXXXAVOLTS & PHASEA - 230/208/60/

Pagina 15 - START UP

Manual 2100-404Page 3FIGURE 1UNIT DIMENSIONSTABLE 2DIMENSIONS OF BASIC UNIT (NOMINAL)ledoMhtdiW)W(htpeD)D(thgieH)H(ylppuSnruteREFG I JKLMNOPQRSTA

Pagina 16 - COMPRESSOR CONTROL MODULE

Manual 2100-404Page 4SHIPPING DAMAGEUpon receipt of equipment, the carton should bechecked for external signs of shipping damage. Ifdamage is foun

Pagina 17 - TROUBLESHOOTING

Manual 2100-404Page 5FILTERSA 1 inch throw away filter is suppled with each unit.The filter slides into position making it easy to service.This fil

Pagina 18 - COOLING PRESSURE

Manual 2100-404Page 6INSTALLATION INSTRUCTIONSWALL MOUNTING INFORMATION1. Two holes, for the supply and return air openings,must be cut through th

Pagina 19 - OPTIONAL ACCESSORIES

Manual 2100-404Page 7NOTE: The voltage should be measured a thefield power connection point in the unit andwhile the unit is operating at full loa